{"title":"Burner Control Boxes","description":"\u003cp\u003eBrowse our Burner Control Boxes collection. New Arrival.\u003c\/p\u003e","products":[{"product_id":"siemens-lmo14113c2-burner-control-box","title":"Siemens LMO14.113C2 Burner Control Box","description":"\u003ch2\u003eSiemens LMO14.113C2 - 230V\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003e BPZ:LMO14.113C2\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe LMO14.113 is a microcontroller-based oil burner control box for the startup, supervision and control of forced draft oil burners in intermittent operation. Maximum oil throughput up to 30 kg\/h.\u003c\/p\u003e\n\u003cp\u003eThe LMO14 control box features: Bridging contact for oil preheater, Monitoring of time for preheater, accurate and reproducible control sequence thanks to digital signal handling, the LMO limits the number of repetitions and has a multicolour indication of the fault status and operational status messages.\u003c\/p\u003e\n\u003cp\u003eIf the mains voltage drops below about AC 165 V, an electronic circuit ensures that the gas burner control will prevent burner startup or without releasing fuel lockout will be initiated.\u003c\/p\u003e\n\u003ch3\u003eLMO14.113C2 Burner Control Box Applications\u003c\/h3\u003e\n\u003cp\u003eThe LM14.113 control box is designed for the startup and supervision of 1 stage forced draft oil burners with a 3 second post ignition time. Yellow-burning flames are supervised with photo resistive detectors QRB..., blue-burning flames with blue-flame sensors QRC... In terms of housing dimensions, electrical connections and flame detectors, the LMO14.113 is identical to the LOA oil burner control boxes.\u003c\/p\u003e\n\u003cp\u003eBurner controls have a designed lifetime of 250,000 burner startup cycles which, under normal operating conditions in heating mode, correspond to approx ƒ¬¬ ten years of usage.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 15s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 10s\u003c\/li\u003e\n\u003cli\u003eLMO14 is for use with 1 stage 30kg oil\/h burners with 3s post ignition time.\u003c\/li\u003e\n\u003cli\u003eUndervoltage detection\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 200g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\" alt=\"Siemens LMO14.113c2 230V Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003ch3\u003eSiemens LMO Dimensions\u003c\/h3\u003e\n\u003cp\u003eIn terms of dimensions, the LMO14.111 A27 burner control boxes are identical to the LME, and LMG control boxes.\u003c\/p\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Box\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMO14.111C2 230V\u003c\/td\u003e\n\u003ctd\u003e54mm\u003c\/td\u003e\n\u003ctd\u003e91mm\u003c\/td\u003e\n\u003ctd\u003e62.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMO14.113C2 230V\u003c\/td\u003e\n\u003ctd\u003e54mm\u003c\/td\u003e\n\u003ctd\u003e91mm\u003c\/td\u003e\n\u003ctd\u003e62.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMO24.011C2 230V\u003c\/td\u003e\n\u003ctd\u003e54mm\u003c\/td\u003e\n\u003ctd\u003e91mm\u003c\/td\u003e\n\u003ctd\u003e62.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310801666301,"sku":"xkw1789510414563","price":53.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lmo14113c2-burner-control-box_1.webp?v=1789510419"},{"product_id":"siemens-lme21330c2-230v-burner-control-box","title":"Siemens LME21.330C2 230v Burner Control Box","description":"\u003ch2\u003eSiemens LME21.330C2 Burner Control Box 230V\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003eBPZ:LME21.330C2\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eLME21.330C2 B27 burner controls are used for the startup and supervision of 1- or 2-stage gas or gas\/oil burners in intermittent operation (of small to medium capacity operation, with or without a fan in intermittent.)\u003c\/p\u003e\n\u003cp\u003eThe flame is supervised by an ionisation probe or flame detector QRA with the ancillary unit, AGQ3A27 for gas\/oil forced draft burners or blue burning flames with blue-flame sensors QRC...\u003c\/p\u003e\n\u003ch3\u003eSiemens LME21.330C2 Burner Control Box Applications\u003c\/h3\u003e\n\u003cp\u003eTypical application: This LME 21.330 is used to supervise 2 stage forced draft burners in intermittent operation. This control box has no damper control.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 30s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 3s\u003c\/li\u003e\n\u003cli\u003eThe LME's housing is made up of heat resistant and flame retardant plastic.\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eUndervoltage Detection\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 160g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg width=\"100%\" alt=\"Siemens LME21.330 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310801731837,"sku":"iki1789510416735","price":99.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme21330c2-230v-burner-control-box_1.webp?v=1789510421"},{"product_id":"siemens-lme21350c2-230v-burner-control-box","title":"Siemens LME21.350C2 230v Burner Control Box","description":"\u003cdiv class=\"row\"\u003e\n\u003ch2\u003e\u003cstrong\u003eSiemens LME21.350C2 Control Box 230v\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003eBPZ:LME21.350C2\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME21.350 C2 Controls 2 stage burners without actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 30s\u003c\/li\u003e\n\u003cli\u003eSafety time: 5s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 4s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u0026lt;\u0026gt;\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3\u003eSiemens LME21.350 C2 Dimensions\u003c\/h3\u003e\n\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME21.350 C2 240V Control Box Dimensions\" width=\"500px\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310802026749,"sku":"iov1789510427239","price":88.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme21350c2-230v-burner-control-box_1.webp?v=1789510431"},{"product_id":"siemens-lmo24255c2-burner-control-box","title":"Siemens LMO24.255C2 Burner Control Box","description":"\u003ch2\u003eSiemens LMO24.255C2 - 230V\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number: \u003c\/strong\u003eBPZ:LMO24.255C2\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe LMO24.255C2 is a microcontroller-based oil burner control box for the startup, supervision and control of forced draft oil burners in intermittent operation. Maximum oil throughput up to 30 kg\/h.\u003c\/p\u003e\n\u003cp\u003eThe LMO24 control box features: Bridging contact for oil preheater, Monitoring of time for preheater, accurate and reproducible control sequence thanks to digital signal handling, the LMO limits the number of repetitions and has a multicolour indication of the fault status and operational status messages.\u003c\/p\u003e\n\u003cp\u003eIf the mains voltage drops below about AC 165 V, an electronic circuit ensures that the gas burner control will prevent burner startup or †™ without releasing fuel †™ lockout will be initiated.\u003c\/p\u003e\n\u003ch3\u003eLMO24.255C2 Burner Control Box Applications\u003c\/h3\u003e\n\u003cp\u003eThe LM24.255C2 control box is designed for the startup and supervision of 2 stage forced draft oil burners with intermittent operation. Yellow-burning flames are supervised with photo resistive detectors QRB..., blue-burning flames with blue-flame sensors QRC... In terms of housing dimensions, electrical connections and flame detectors, the LMO24.255C2 is identical to the LOA oil burner control boxes.\u003c\/p\u003e\n\u003cp\u003eBurner controls have a designed lifetime of 250,000 burner startup cycles which, under normal operating conditions in heating mode, correspond to approx ƒ¬¬ ten years of usage.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 25s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 5s\u003c\/li\u003e\n\u003cli\u003eLMO24 is for use with 2 stage 30kg oil\/h burners.\u003c\/li\u003e\n\u003cli\u003eUnder voltage detection\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 200g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\" alt=\"Dimensions For LMO24.255c2\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Box\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMO24.255C2 230V\u003c\/td\u003e\n\u003ctd\u003e54mm\u003c\/td\u003e\n\u003ctd\u003e91mm\u003c\/td\u003e\n\u003ctd\u003e62.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310802157821,"sku":"kin1789510428655","price":78.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lmo24255c2-burner-control-box_1.webp?v=1789510432"},{"product_id":"siemens-lme21550c2-230v-burner-control-box","title":"Siemens LME21.550C2 230v Burner Control Box","description":"\u003ch2\u003e\u003cstrong\u003eSiemens LME21.550C2 Control Box 230v\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number: \u003c\/strong\u003eBPZ:LME21.550C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME21.550 C2 Controls 2 stage burners without actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 240V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 50s\u003c\/li\u003e\n\u003cli\u003eSafety time: 5s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 4s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME21.550 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME21.550 C2 240V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310802190589,"sku":"cby1789510429614","price":107.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme21550c2-230v-burner-control-box_1.webp?v=1789510433"},{"product_id":"siemens-lme23351c2-230v-burner-control-box","title":"Siemens LME23.351C2 230v Burner Control Box","description":"\u003ch2\u003eSiemens LME23.351C2 Burner Control Box 230V\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number: \u003c\/strong\u003eBPZ:LME23.351C2\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eLME23.351C2 burner controls are used for the startup and supervision of 1- or 2-stage gas or gas\/oil burners in intermittent operation (of small to medium capacity operation, with or without a fan in intermittent.)\u003c\/p\u003e\n\u003ch3\u003eLME23.351C2 Burner Control Box Applications\u003c\/h3\u003e\n\u003cp\u003eTypical application: This LME23.351 is used to supervise 2 stage forced draft burners, with actuator control.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 30s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 5s\u003c\/li\u003e\n\u003cli\u003eThe LME's housing is made up of heat resistant and flame retardant plastic.\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eUndervoltage Detection\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 160g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg width=\"100%\" alt=\"Siemens LME23.351c2 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310803173629,"sku":"dsq1789510442544","price":127.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme23351c2-230v-burner-control-box_1.webp?v=1789510446"},{"product_id":"siemens-lme21130c2-230v-burner-control-box","title":"Siemens LME21.130C2 230v Burner Control Box","description":"\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME21.130 C2 Controls2 stage burners without actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 240V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 7s\u003c\/li\u003e\n\u003cli\u003eSafety time: 3s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 2s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u0026lt;\u0026gt;\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3\u003eSiemens LME21.130 C2 Dimensions\u003c\/h3\u003e\n\u003cimg width=\"500px\" alt=\"Siemens LME21.130 C2 240V Control Box Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" class=\"img-responsive\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310803239165,"sku":"vop1789510443634","price":102.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme21130c2-230v-burner-control-box_1.webp?v=1789510447"},{"product_id":"siemens-lmo24111c2-burner-control-box","title":"Siemens LMO24.111C2 Burner Control Box","description":"\u003ch2\u003eSiemens LMO24.111C2- 230V\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003e BPZ:LMO24.111C2\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe LMO24.111C2 is a microcontroller-based oil burner control box for the startup, supervision and control of forced draft oil burners in intermittent operation. Maximum oil throughput up to 30 kg\/h.\u003c\/p\u003e\n\u003cp\u003eThe LMO24 control box features: Bridging contact for oil preheater, Monitoring of time for preheater, accurate and reproducible control sequence thanks to digital signal handling, the LMO limits the number of repetitions and has a multicolour indication of the fault status and operational status messages.\u003c\/p\u003e\n\u003cp\u003eIf the mains voltage drops below about AC 165 V, an electronic circuit ensures that the gas burner control will prevent burner startup or without releasing fuel lockout will be initiated.\u003c\/p\u003e\n\u003ch3\u003eSiemens LMO24.111C2 Burner Control Box Applications\u003c\/h3\u003e\n\u003cp\u003eThe LM24.111C2 control box is designed for the startup and supervision of 2 stage forced draft oil burners with intermittent operation. Yellow-burning flames are supervised with photo resistive detectors QRB..., blue-burning flames with blue-flame sensors QRC... In terms of housing dimensions, electrical connections and flame detectors, the LMO24.111 is identical to the LOA oil burner control boxes.\u003c\/p\u003e\n\u003cp\u003eBurner controls have a designed lifetime of 250,000 burner startup cycles which, under normal operating conditions in heating mode, correspond to approx ƒ¬¬ ten years of usage.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 15s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 10s\u003c\/li\u003e\n\u003cli\u003eLMO24 is for use with 2 stage 30kg oil\/h burners.\u003c\/li\u003e\n\u003cli\u003eUnder-voltage detection\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 200g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\" alt=\"Dimensions For LMO24.11c2\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Box\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMO14.111C2 230V\u003c\/td\u003e\n\u003ctd\u003e54mm\u003c\/td\u003e\n\u003ctd\u003e91mm\u003c\/td\u003e\n\u003ctd\u003e62.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMO14.113C2 230V\u003c\/td\u003e\n\u003ctd\u003e54mm\u003c\/td\u003e\n\u003ctd\u003e91mm\u003c\/td\u003e\n\u003ctd\u003e62.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLMO24.111C2 230V\u003c\/td\u003e\n\u003ctd\u003e54mm\u003c\/td\u003e\n\u003ctd\u003e91mm\u003c\/td\u003e\n\u003ctd\u003e62.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310803304701,"sku":"tdu1789510424252","price":66.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lmo24111c2-burner-control-box_1.webp?v=1789510451"},{"product_id":"siemens-lme23331c2-230v-burner-control-box","title":"Siemens LME23.331C2 230v Burner Control Box","description":"\u003ch2 class=\"row\"\u003eSiemens LME23.331C2 Control Box 230v\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003e BPZ:LME23.331C2\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME23.331 C2 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 30s\u003c\/li\u003e\n\u003cli\u003eSafety time: 3s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 2s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 3s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u0026lt;\u0026gt;\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3\u003eSiemens LME23.331 C2 Dimensions\u003c\/h3\u003e\n\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME23.331 C2 240V Control Box Dimensions\" width=\"500px\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310803927293,"sku":"rwk1789510449446","price":113.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme23331c2-230v-burner-control-box_1.webp?v=1789510454"},{"product_id":"siemens-lme21350c1-110v-burner-control-box","title":"Siemens LME21.350C1 110v Burner Control Box","description":"\u003ch2 class=\"row\"\u003eSiemens LME21.350C1 Control Box 110v\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003e BPZ:LME21.350C1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME21.350 C1 Controls 2 stage burners without actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 110V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 30s\u003c\/li\u003e\n\u003cli\u003eSafety time: 5s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 4s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME21.350 C1 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME21.350 C1 110V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310803960061,"sku":"kep1789510454298","price":114.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme21350c1-110v-burner-control-box_1.webp?v=1789510460"},{"product_id":"siemens-lme11230c2-230v-burner-control-box","title":"Siemens LME11.230C2 230v Burner Control Box","description":"\u003ch2\u003eSiemens LME11.230C2 Burner Control Box 230V\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003eBPZ:LME11.230C2\u003c\/p\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eSiemens LME11.230C2 burner controls are used for the startup and supervision of 1- or 2-stage gas or gas\/oil burners in intermittent operation (of small to medium capacity, operation, with or without a fan in intermittent.)\u003c\/p\u003e\n\u003cp\u003eThe flame is supervised by an ionisation probe or flame detector QRA with the ancillary unit, AGQA27 for gas\/oil forced draft burners or blue burning flames with blue-flame detectors QRC...\u003c\/p\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe housing is made up of heat resistant and flame retardant plastic.\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eUndervoltage Detection\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 160g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\" alt=\"Siemens LME11.230 Dimensions\" width=\"100%\"\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310803992829,"sku":"wsp1789510455220","price":74.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme11230c2-230v-burner-control-box_1.webp?v=1789510459"},{"product_id":"siemens-lme39100c2-230v-burner-control-box","title":"Siemens LME39.100C2 230v Burner Control Box","description":"\u003ch2 class=\"row\"\u003eSiemens LME39.100C2 - 230v\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003e BPZ:LME39.100C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME39.100 C2 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 30s\u003c\/li\u003e\n\u003cli\u003eSafety time: 3s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 3s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 3s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME39.100 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME39.100 C2 240V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310804287741,"sku":"sek1789510460109","price":128.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme39100c2-230v-burner-control-box_1.webp?v=1789510464"},{"product_id":"siemens-lme39400c2-230v-burner-control-box","title":"Siemens LME39.400C2 230v Burner Control Box","description":"\u003ch2 class=\"row\"\u003eSiemens LME39.400C2 Control Box 230v\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number: \u003c\/strong\u003eBPZ:LME39.400C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME39.400 C2 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003eSafety time: 5s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 3s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 3s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME39.400 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME39.400 C2 240V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310804320509,"sku":"ned1789510461763","price":138.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme39400c2-230v-burner-control-box_1.webp?v=1789510465"},{"product_id":"siemens-lme22232c2-230v-burner-control-box","title":"Siemens LME22.232C2 230v Burner Control Box","description":"\u003ch2\u003eSiemens LME22.232C2 Control Box 230v\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eNuway Part number:\u003c\/strong\u003e BN12058201\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003e BPZ:LME22.232C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME22.232 C2 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 20s\u003c\/li\u003e\n\u003cli\u003eSafety time: 3s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 2s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 3s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME22.232 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME22.232 C2 240V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310804353277,"sku":"lzn1789510462204","price":93.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme22232c2-230v-burner-control-box_1.webp?v=1789510465"},{"product_id":"siemens-lme22331c2-230v-burner-control-box","title":"Siemens LME22.331C2 230v Burner Control Box","description":"\u003ch2\u003e\u003cstrong\u003eSiemens LME22.331C2 - 230v\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003eBPZ:LME22.331C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME22.331 C2 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 240V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 30s\u003c\/li\u003e\n\u003cli\u003eSafety time: 3s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 2s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 3s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME22.331 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME22.331 C2 240V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310804386045,"sku":"kjh1789510465520","price":105.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme22331c2-230v-burner-control-box_1.webp?v=1789510469"},{"product_id":"siemens-lme41052c2-230v-burner-control-box","title":"Siemens LME41.052C2 230v Burner Control Box","description":"\u003ch2\u003e\u003cstrong\u003eSiemens LME41.052C2 Control Box 230v\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number: \u003c\/strong\u003eBPZ:LME41.052C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME41.052 C2 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePurge time: 10s\u003c\/li\u003e\n\u003cli\u003eSafety time: 5s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 1s\u003c\/li\u003e\n\u003cli\u003ePostignition time: 4.5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME41.052 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME41.053 C2 240V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310804418813,"sku":"bbw1789510466931","price":72.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme41052c2-230v-burner-control-box_1.webp?v=1789510470"},{"product_id":"siemens-lme41051c2-230v-burner-control-box","title":"Siemens LME41.051C2 230v Burner Control Box","description":"\u003ch2\u003eSiemens LME41.051C2 - 230V\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003eBPZ:LME41.051C2\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eLME41.051C2 burner controls are used for the startup and supervision of 1- or 2-stage gas or gas\/oil burners in intermittent operation (of small to medium capacity operation, with or without a fan in intermittent.)\u003c\/p\u003e\n\u003cp\u003eThe flame is supervised by an ionisation probe or flame detector QRA with the ancillary unit, AGQ3A27 for gas\/oil forced draft burners or blue burning flames with blue-flame sensors QRC...\u003c\/p\u003e\n\u003ch3\u003eSiemens LME41.051C2 Burner Control Box Applications\u003c\/h3\u003e\n\u003cp\u003eTypical application: This LME41.051 is used to supervise 2 stage forced draft burners, with actuator control.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 1s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 5s\u003c\/li\u003e\n\u003cli\u003eThe LME's housing is made up of heat resistant and flame retardant plastic.\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eUndervoltage Detection\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 160g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\" alt=\"LME41.051C2 Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310804484349,"sku":"akz1789510468559","price":66.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme41051c2-230v-burner-control-box_1.webp?v=1789510472"},{"product_id":"siemens-lme41054c2-230v-burner-control-box","title":"Siemens LME41.054C2 230v Burner Control Box","description":"\u003ch2\u003eSiemens LME41.054C2 - 230v\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number: \u003c\/strong\u003eBPZ:LME41.054C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME41.054 C2 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 240V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePurge time: 1s\u003c\/li\u003e\n\u003cli\u003eSafety time: 5s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 1s\u003c\/li\u003e\n\u003cli\u003ePostignition time: 4.5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME41.054 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME41.054 C2 240V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310804910333,"sku":"hpy1789510472278","price":72.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme41054c2-230v-burner-control-box_1.webp?v=1789510477"},{"product_id":"siemens-lme44190c2-230v-burner-control-box","title":"Siemens LME44.190C2 230v Burner Control Box","description":"\u003ch2\u003e\u003cstrong\u003eSiemens LME44.190C2 - 230v\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number: \u003c\/strong\u003eBPZ:LME44.190C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME44.190 C2 Controls atmospheric burners\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePurge time:12s\u003c\/li\u003e\n\u003cli\u003eSafety time: 10s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 0.5s\u003c\/li\u003e\n\u003cli\u003ePost-ignition time: 9.5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME44.190 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME44.190 C2 240V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310804943101,"sku":"vpo1789510479646","price":114.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme44190c2-230v-burner-control-box_1.webp?v=1789510483"},{"product_id":"siemens-lme44057c2-230v-burner-control-box","title":"Siemens LME44.057C2 230v Burner Control Box","description":"\u003ch2\u003eSiemens LME44.057C2- 230V\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003eBPZ:LME44.057C2\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eLME44.057C2 burner controlsare used for the startup and supervision of 1- or 2-stage gas or gas\/oil burners in intermittent operation (of small to medium capacity operation, with or without a fan in intermittent.)\u003c\/p\u003e\n\u003cp\u003eThe flame is supervised by an ionisation probe or flame detector with the ancillary unit, AGQ3A27 for gas\/oil forced draft burners or blue burning flames with blue-flame sensors QRC...\u003c\/p\u003e\n\u003ch3\u003eSiemens LME44.057C2 Burner Control Box Applications\u003c\/h3\u003e\n\u003cp\u003eTypical application: This LME44.057is used to supervise 2 stage forced draft burners, with actuator control.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 9s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 5s\u003c\/li\u003e\n\u003cli\u003ePre-ignition time: 2s\u003c\/li\u003e\n\u003cli\u003eThe LME's housing is made up of heat resistant and flame retardant plastic.\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eUndervoltage Detection\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 160g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\" alt=\"LME44.057C2 Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310804975869,"sku":"gjd1789510480480","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme44057c2-230v-burner-control-box_1.webp?v=1789510484"},{"product_id":"siemens-lme71000a1-110v-microprocessor-burner-controls","title":"Siemens LME71.000A1 110v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-12\"\u003e\n\u003ch2\u003eSiemens LME71.000A1 Burner Control Box 110V\u003c\/h2\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan data-mce-fragment=\"1\"\u003eburner control\u003c\/span\u003eLME71.000A1 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n\u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u0026lt;\u0026gt;\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003ch3\u003eLME71.000A1 Burner Control Box Applications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003eThe LME71 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 9s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 5s\u003c\/li\u003e\n\u003cli\u003ePre-ignition time: 2s\u003c\/li\u003e\n\u003cli\u003eUndervoltage detection\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 110VAC\u003c\/li\u003e\n\u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n\u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12\"\u003e\u003cimg width=\"100%\" alt=\"LME71.000A1 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\u0026amp;width=700\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u0026lt;\u0026gt;\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12\"\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Box\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLME71.000A1 230V\u003c\/td\u003e\n\u003ctd\u003e180mm\u003c\/td\u003e\n\u003ctd\u003e120mm\u003c\/td\u003e\n\u003ctd\u003e52.6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310805106941,"sku":"mga1789510480912","price":205.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme71000a1-110v-microprocessor-burner-controls_1.webp?v=1789510486"},{"product_id":"siemens-lme41091c2-230v-burner-control-box","title":"Siemens LME41.091C2 230v Burner Control Box","description":"\u003ch2\u003eSiemens LME41.091C2- 230V\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003eBPZ:LME41.091C2\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eLME41.091C2 burner controls are used for the startup and supervision of 1- or 2-stage gas or gas\/oil burners in intermittent operation (of small to medium capacity operation, with or without a fan in intermittent.)\u003c\/p\u003e\n\u003cp\u003eThe flame is supervised by an ionisation probe or flame detector QRA with the ancillary unit, AGQ3A27 for gas\/oil forced draft burners or blue burning flames with blue-flame sensors QRC...\u003c\/p\u003e\n\u003ch3\u003eSiemens LME41.091C2 Applications\u003c\/h3\u003e\n\u003cp\u003eTypical application: This LME41.091 is used to supervise 2 stage forced draft burners, with actuator control.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 1s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 10s\u003c\/li\u003e\n\u003cli\u003ePre-ignitioe: 10s\u003c\/li\u003e\n\u003cli\u003eThe LME's housing is made up of heat resistant and flame retardant plastic.\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eUndervoltage Detction\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 160g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\" alt=\"LME41.091C2 Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310805270781,"sku":"xuz1789510480384","price":76.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme41091c2-230v-burner-control-box_1.webp?v=1789510487"},{"product_id":"siemens-lme71000a2-230v-microprocessor-burner-controls","title":"Siemens LME71.000A2 230v Microprocessor Burner Controls","description":"\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-12\"\u003e\n\u003ch2\u003eSiemens LME71.000A2 Burner Control Box 230V\u003c\/h2\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan data-mce-fragment=\"1\"\u003eburner control\u003c\/span\u003eLME71.000A2 is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity.\u003c\/p\u003e\n\u003cp\u003eThe fuel-air ratio can be set either via an air damper actuator - acting on mechanical or pneumatic ratio control - or via pulse width modulated fans and pneumatic ratio control. The flame supervision supervised with ionization probe and with UV flame detector QRA2..., QRA4.U or QRA10...\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u0026lt;\u0026gt;\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003ch3\u003eLME71.000A2 Burner Control Box Applications\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003eThe LME71 is used for the startup and supervision of multistage or modulating forced draft burners and atmospheric gas burners in intermittent operation.\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\"\u003ewFeatures\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cul\u003e\n\u003cli\u003eUndervoltage detection\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eElectrical remote reset facility\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60\u003c\/li\u003e\n\u003cli\u003eMulticolor indication of fault status and operating state messages\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 490g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME71_Dimensions.jpg?v=1575996162\u0026amp;width=700\" alt=\"LME71.000A1 Dimensions\" width=\"100%\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310805434621,"sku":"tla1789510484871","price":193.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme71000a2-230v-microprocessor-burner-controls_1.webp?v=1789510489"},{"product_id":"siemens-lme21230c2-230v-burner-control-box","title":"Siemens LME21.230C2 230v Burner Control Box","description":"\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME21.230 C2 Controls 2 stage burners without actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 240V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 20s\u003c\/li\u003e\n\u003cli\u003eSafety time: 3s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 2s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u0026lt;\u0026gt;\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3\u003eSiemens LME21.230 C2 Dimensions\u003c\/h3\u003e\n\u003cimg width=\"500px\" alt=\"Siemens LME21.230 C2 240V Control Box Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" class=\"img-responsive\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310805860605,"sku":"vnd1789510490750","price":112.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme21230c2-230v-burner-control-box_1.webp?v=1789510495"},{"product_id":"siemens-lme21130c1-110v-burner-control-box","title":"Siemens LME21.130C1 110v Burner Control Box","description":"\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME21.130 C1 Controls2 stage burners without actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 110V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePrepurge time: 7s\u003c\/li\u003e\n\u003cli\u003eSafety time: 3s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 2s\u003c\/li\u003e\n\u003cli\u003eSpecified time for air pressure signal: 5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u0026lt;\u0026gt;\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-6\"\u003e\n\u003ch3\u003eSiemens LME21.130 C1 Dimensions\u003c\/h3\u003e\n\u003cimg width=\"500px\" alt=\"Siemens LME21.130 C1 110V Control Box Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" class=\"img-responsive\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310805991677,"sku":"xcs1789510498602","price":95.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme21130c1-110v-burner-control-box_1.webp?v=1789510507"},{"product_id":"siemens-lme41092c2-230v-burner-control-box","title":"Siemens LME41.092C2 230v Burner Control Box","description":"\u003ch2 class=\"row\"\u003eSiemens LME41.092C2 - 230v\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003e BPZ:LME41.092C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME41.092 C2 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 240V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 2.5s\u003c\/li\u003e\n\u003cli\u003ePurge time: 1s\u003c\/li\u003e\n\u003cli\u003eSafety time: 10s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 1s\u003c\/li\u003e\n\u003cli\u003ePost-ignition time: 9s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME41.092 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME41.092 C2 240V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310806024445,"sku":"rrr1789510503358","price":69.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme41092c2-230v-burner-control-box_1.webp?v=1789510508"},{"product_id":"siemens-lme22131c2-230v-burner-control-box","title":"Siemens LME22.131C2 230v Burner Control Box","description":"\u003ch2\u003eSiemens LME22.131C2 Control Box 230V\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number:\u003c\/strong\u003eBPZ:LME22.131C2\u003c\/p\u003e\n\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eLME22.131C2 burner controls are used for the startup and supervision of 1- or 2-stage gas or gas\/oil burners in intermittent operation (of small to medium capacity operation, with or without a fan in intermittent.)\u003c\/p\u003e\n\u003cp\u003eThe flame is supervised by an ionisation probe or flame detector QRA with the ancillary unit, AGQ3A27 for gas\/oil forced draft burners or blue burning flames with blue-flame sensors QRC...\u003c\/p\u003e\n\u003ch3\u003eLME22.131C2 Burner Control Box Applications\u003c\/h3\u003e\n\u003cp\u003eTypical application: This LME22.131C2 is used to supervise 2 stage forced draft burners, with actuator control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Time: 7s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 3s\u003c\/li\u003e\n\u003cli\u003eThe LME's housing is made up of heat resistant and flame retardant plastic.\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230VAC\u003c\/li\u003e\n\u003cli\u003eUndervoltage Detection\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eOperation Temperature: -20 - +60 °C\u003c\/li\u003e\n\u003cli\u003eMounting Position: Optional\u003c\/li\u003e\n\u003cli\u003eWeight: Approx. 160g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Diagram.jpg?2000=\u0026amp;width=700\" alt=\"Siemens LME22.131 Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310806614269,"sku":"yal1789510518658","price":102.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme22131c2-230v-burner-control-box_1.webp?v=1789510523"},{"product_id":"siemens-lme44057c1-110v-burner-control-box","title":"Siemens LME44.057C1 110v Burner Control Box","description":"\u003ch2\u003eSiemens LME44.057C1 - 110v\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Numbers:\u003c\/strong\u003e BPZ:LME44.057C1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME44.057 C1 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 110V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 16s\u003c\/li\u003e\n\u003cli\u003ePurge time: 9s\u003c\/li\u003e\n\u003cli\u003eSafety time: 5s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 2s\u003c\/li\u003e\n\u003cli\u003ePost-ignition time: 4.5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME44.057 C1 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" alt=\"Siemens LME44.057 C1 110V Control Box Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310810808573,"sku":"xqt1789510605630","price":124.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme44057c1-110v-burner-control-box_1.webp?v=1789510615"},{"product_id":"honeywell-dkw-972-mod-05-230v-0322005u-burner-control-box","title":"Honeywell DKW 972 MOD 05 230v 0322005U Burner Control Box","description":"\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12\"\u003e\n\u003ch3\u003eSatronic DKW 972 MOD 05 230v Control Box\u003c\/h3\u003e\n\u003ch3\u003eAlternative Part Number: C21550P\u003c\/h3\u003e\n\u003cp\u003eThe DKW 972 is for oil burners on direct air heaters and for burners above 30 kg\/h throughput for intermittent operation, with or without oil preheater, 1- or 2-stage, recycling and post-purge after a loss of flame.\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12\"\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12\"\u003eManufacturer: Satronic\u003c\/div\u003e\n\u003cdiv class=\"col-md-12\"\u003eVoltage: 230VAC\u003c\/div\u003e\n\u003cdiv class=\"col-md-12\"\u003e\n\u003cdiv title=\"Page 1\" class=\"page\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe microprocessor based programming sequence ensures extremely stable timings independent of voltage variations, ambient temperature and\/or switch-on cycles.\u003c\/li\u003e\n\u003cli\u003eThe built-in information system not only provides a continuous monitoring of the actual state of the box but also informs about the cause of a possible lock out. The lock out cause is stored in such a way that it can be retrieved even after a power failure.\u003c\/li\u003e\n\u003cli\u003eThe control box DKW 972 MOD 5 is designed for maximum safety in case of fluctuations in the voltage supply. If the mains voltage drops below the permitted level, operation is interrupted and the control box automatically prevents the start sequence from being repeated. In this way, the safety of the system is not put at risk by a drop in the mains voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv title=\"Page 1\" class=\"page\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cbr\u003e\n\u003cdiv class=\"column\"\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003eOperating voltage220 \/ 240 V (-15... +10%) 50\/60 Hz (±5%)\u003cbr\u003e 110 \/ 120 V (-15... +10%) 50\/60 Hz (±5%)\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv title=\"Page 1\" class=\"page\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFlame detectors: MZ 770 S\u003c\/p\u003e\n\u003cp\u003eLight sensitivity: IRD 1010 \/UVD 970\u003c\/p\u003e\n\u003cp\u003eWeight including Wiring base: 190g\u003c\/p\u003e\n\u003cp\u003eMounting position: Any\u003c\/p\u003e\n\u003cp\u003eProtection class: IP40\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":71310823227645,"sku":"zbt1789510916113","price":152.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/honeywell-dkw-972-mod-05-230v-0322005u-burner-control-box_1.webp?v=1789510920"},{"product_id":"honeywell-dkg-972-mod-10-230v-burner-control-box","title":"Honeywell DKG 972 MOD 10 230v Burner Control Box","description":"\u003cp\u003e\u003cstrong\u003eHoneywell Part Number:\u003c\/strong\u003e 0432010\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications for:\u003c\/h3\u003e\n\u003ch5\u003eHoneywell \/ Satronic DKG 972-N MOD 10 Control Box:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDKG 972 MOD 10 controls 2 stage atmospheric gas burners\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 220\/ 240V\u003c\/li\u003e\n\u003cli\u003eWaiting Time at Start-up: 12s\u003c\/li\u003e\n\u003cli\u003eStray light monitoring: 5s\u003c\/li\u003e\n\u003cli\u003ePre-ignition time: 3s\u003c\/li\u003e\n\u003cli\u003ePost-ignition time: 9s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 10s\u003c\/li\u003e\n\u003cli\u003eDelay 2nd-stage: 25s\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":71310824341757,"sku":"dcw1789510930802","price":156.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/honeywell-dkg-972-mod-10-230v-burner-control-box_1.webp?v=1789510935"},{"product_id":"danfoss-obc8210-057h8702-burner-control-box","title":"Danfoss OBC82.10 057H8702 Burner Control Box","description":"\u003ch2\u003eDanfoss OBC82.10 Control Box *OBSOLETE*\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDanfoss OBC 82.10 controls and supervises 2 stage oil burners\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 220\/ 240V\u003c\/li\u003e\n\u003cli\u003ePre-purge time: 13s\u003c\/li\u003e\n\u003cli\u003ePre-ignition time: 13s\u003c\/li\u003e\n\u003cli\u003ePost-ignition time: 15\u003c\/li\u003e\n\u003cli\u003eInterval V1-V2: 15s\u003c\/li\u003e\n\u003cli\u003eSafty time: 10s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDanfoss OBC 82.10 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg width=\"500px\" alt=\"Danfoss OBC 82.10 057H8102 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/OBC82_Dimensions.PNG?v=1588073827\u0026amp;width=700\" class=\"img-responsive\"\u003e\u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":71310824472829,"sku":"hyi1789510934221","price":67.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/danfoss-obc8210-057h8702-burner-control-box_1.webp?v=1789510940"},{"product_id":"honeywell-tf974-230v-02524-burner-control-box","title":"Honeywell TF974 230v 02524 Burner Control Box","description":"\u003cp\u003e\u003cstrong\u003eHoneywell Part Number:\u003c\/strong\u003e 02524\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications for:\u003c\/h3\u003e\n\u003ch4\u003eHoneywell TF974 230v Control Box:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell TF 974 Application: Oil Burners up to 30kg\/h with oil preheater\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 220\/ 240V\u003c\/li\u003e\n\u003cli\u003ePre-purge time: 12s\u003c\/li\u003e\n\u003cli\u003ePre-igniton time: 12s\u003c\/li\u003e\n\u003cli\u003ePost-ignition time: 20s\u003c\/li\u003e\n\u003cli\u003eLockout safety time: 10s\u003c\/li\u003e\n\u003cli\u003eDelay time to oil valve 2: 20s\u003c\/li\u003e\n\u003cli\u003eReset time from lockout: 60s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHoneywell TF 974 02524 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg width=\"100%\" alt=\"Honeywell TF 974 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/TF_974_Dimensions.PNG?v=1588067607\u0026amp;width=700\" class=\"img-responsive\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":71310824505597,"sku":"hji1789510943512","price":65.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/honeywell-tf974-230v-02524-burner-control-box_1.webp?v=1789510947"},{"product_id":"honeywell-tf8343-230v-02234-burner-control-box","title":"Honeywell TF834.3 230v 02234 Burner Control Box","description":"\u003cp\u003e\u003cstrong\u003eHoneywell Part Number:\u003c\/strong\u003e 02234\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications for:\u003c\/h3\u003e\n\u003ch4\u003eHoneywell TF834.3 230v Control Box:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell TF 834.3 Application: Oil Burners up to 30kg\/h with oil preheater\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 220\/ 240V\u003c\/li\u003e\n\u003cli\u003ePre-purge time: 12s\u003c\/li\u003e\n\u003cli\u003ePre-igniton time: 12s\u003c\/li\u003e\n\u003cli\u003ePost-ignition time: 20s\u003c\/li\u003e\n\u003cli\u003eLockout safety time: 10s\u003c\/li\u003e\n\u003cli\u003eDelay time to oil valve 2: 40s\u003c\/li\u003e\n\u003cli\u003eReset time from lockout: 60s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHoneywell TF 834.3 02234 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg width=\"100%\" alt=\"Honeywell TF 834v.3 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/TF_Dimensions.PNG?v=1587996808\u0026amp;width=700\" class=\"img-responsive\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":71310824964349,"sku":"ldq1789510949215","price":74.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/honeywell-tf8343-230v-02234-burner-control-box_1.webp?v=1789510953"},{"product_id":"honeywell-dmg-970-mod-03-230v-burner-control-box","title":"Honeywell DMG 970 MOD 03 230v Burner Control Box","description":"\u003cp\u003e\u003cstrong\u003eHoneywell Part Number:\u003c\/strong\u003e 0450003U\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications for:\u003c\/h3\u003e\n\u003ch4\u003eHoneywell \/ Satronic DMG 970 MOD 03 Control Box:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDMG 970 MOD 3 Controls gas and duel fuel burners\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 220\/ 240V\u003c\/li\u003e\n\u003cli\u003eWaiting Time at Start-up: 0s\u003c\/li\u003e\n\u003cli\u003eMax Reaction Time For Air Proving Switch: 60s\u003c\/li\u003e\n\u003cli\u003eSupervised pre-purge Time: 40s\u003c\/li\u003e\n\u003cli\u003ePre-ignition time: 3s\u003c\/li\u003e\n\u003cli\u003eIgnition Time: 5.5s\u003c\/li\u003e\n\u003cli\u003eSafety Time: 3s\u003c\/li\u003e\n\u003cli\u003eStray light monitoring: 5s\u003c\/li\u003e\n\u003cli\u003eDelay 2nd-stage: 12.5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHoneywell DMG 970 MOD 03 0450003U Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"img-responsive mx-auto\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/DMG_Dimensions.PNG?v=1588064375\u0026amp;width=700\" alt=\"Honeywell DMG 970 MOD 03 Dimensions\" width=\"100%\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":71310824997117,"sku":"rls1789510950197","price":199.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/honeywell-dmg-970-mod-03-230v-burner-control-box_1.webp?v=1789510954"},{"product_id":"honeywell-dkg-972-mod-05-230v-0432005u-burner-control-box","title":"Honeywell DKG 972 MOD 05 230v 0432005U Burner Control Box","description":"\u003cp\u003e\u003cstrong\u003eHoneywell Part Number:\u003c\/strong\u003e 0432005U\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications for:\u003c\/h3\u003e\n\u003ch5\u003eHoneywell \/ Satronic DKG 972-N MOD 05 Control Box:\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces TFI812.2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDKG 972-N MOD 05 Controls 2 Stage Atmospheric burners\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: 220\/240V\u003c\/li\u003e\n\u003cli\u003eSensitivity: 1 \u003c\/li\u003e\n\u003cli\u003eIonisation probe.\u003c\/li\u003e\n\u003cli\u003eInfrared flicker detector IRD 1020.1\u003c\/li\u003e\n\u003cli\u003eUV flame sensor UVD 971\u003c\/li\u003e\n\u003cli\u003eIP Rating: IP40\u003c\/li\u003e\n\u003cli\u003eTemperature: -20° C - +60° C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHoneywell DKG 972-N MOD 05 0432005U Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg width=\"100%\" alt=\"Honeywell DKG 972-N MOD 05 Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/DKG_Dimensions.PNG?v=1588068850\u0026amp;width=700\" class=\"img-responsive mx-auto\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":71310827323645,"sku":"pak1789510994067","price":131.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/honeywell-dkg-972-mod-05-230v-0432005u-burner-control-box_1.webp?v=1789510997"},{"product_id":"siemens-agk30-auxiliary-module-lfs1","title":"Siemens AGK30 Auxiliary module (LFS1)","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eConnection of UV flame detectors QRA2M and QRA10M is only permitted if additional module AGK30 is used. Additional module AGK30 must always be connected within plug-in base AGK11.7 in terminal areas 1¬¦7. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock\u003c\/span\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310840168701,"sku":"dki1789511316653","price":32.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-agk30-auxiliary-module-lfs1_1.jpg?v=1789511320"},{"product_id":"siemens-lme44056c2-230v-burner-control-box","title":"Siemens LME44.056C2 230v Burner Control Box","description":"\u003ch2\u003e\u003cstrong\u003eSiemens LME44.056C2 - 230v\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiemens Part Number: \u003c\/strong\u003eBPZ:LME44.056C2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens LME44.056 C2 Controls 2 stage burners with actuator control\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: 230V\u003c\/li\u003e\n\u003cli\u003eWaiting time: 16s\u003c\/li\u003e\n\u003cli\u003ePurge time: 9s\u003c\/li\u003e\n\u003cli\u003eSafety time: 5s\u003c\/li\u003e\n\u003cli\u003ePreignition time: 2s\u003c\/li\u003e\n\u003cli\u003ePost-ignition time: 4.5s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSiemens LME44.056 C2 Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg width=\"100%\" alt=\"Siemens LME44.057 C2 240V Control Box Dimensions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0016\/1257\/8876\/files\/LME_Dimensions.PNG?v=1588752646\u0026amp;width=700\" class=\"img-responsive\"\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310873067773,"sku":"icy1789512095227","price":111.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/siemens-lme44056c2-230v-burner-control-box_1.webp?v=1789512123"},{"product_id":"lmo14111c2-siemens-oil-and-gas-burner-control","title":"LMO14.111C2 Siemens Oil and Gas burner control","description":"\u003cp\u003eLMO14.111C2 - Oil burner control, 1-stage, QRB\/QRC, up to 30kg\/h, TSA=10s, t3n=10s, AC230V\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":71310897381629,"sku":"vql1789512553452","price":49.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/0322\/2013\/files\/lmo14111c2-siemens-oil-and-gas-burner-control_1.webp?v=1789512580"}],"url":"https:\/\/maximaliststyle.shop\/collections\/burner-control-boxes.oembed?page=2","provider":"My Store","version":"1.0","type":"link"}